- Delivering reliable, high-power electrical supply to subsea processing equipment — pumps, compressors, and control systems — at water depths of hundreds or thousands of metres requires a subsea power distribution architecture that is fundamentally different from onshore industrial power systems, and is one of the primary enabling technologies for the “subsea factory” concept.
- Variable Speed Drives (VSDs) — which control the speed of subsea electric motors by varying the frequency and voltage of the power supply — are the primary tool for efficient subsea pump and compressor control, but designing VSDs for permanent subsea installation at depth involves overcoming pressure compensation, heat dissipation, and reliability challenges that don’t exist in onshore installations.
- Long-distance subsea power transmission — delivering megawatts of power over distances of 100-300 km from a host platform or shore connection to subsea equipment — requires medium-voltage or high-voltage DC transmission with specialised subsea power umbilicals, power conversion equipment, and control systems that are at the leading edge of current electrical engineering capability.
The Subsea Power Challenge
When the oil and gas industry began deploying subsea trees and manifolds in the 1980s and 1990s, the power requirements were modest — hydraulic systems for valve actuation (providing force through pressurised fluid rather than electrical motors), and low-power electrical systems for instrumentation, sensors, and telemetry. A typical subsea control system might require 1-5 kW of electrical power per wellhead, easily delivered through a conventional multi-core umbilical from the surface.
The transition to subsea processing — multiphase pumps, wet gas compressors, separation systems, and the associated electrical equipment — has transformed the power requirement. A multiphase pump for a major deepwater field might require 2-5 MW of electrical power per pump. A subsea gas compression system, like the Åsgard ASC described earlier, requires 12.5 MW per compressor. When multiple subsea processing systems operate simultaneously in a major field development, the total subsea power requirement can reach 30-100 MW — comparable to the power consumption of a small city.
Delivering this power to the seabed, reliably and efficiently, from a surface facility that may be tens of kilometres away, is one of the key engineering challenges of the subsea factory vision. The physics are unforgiving: electrical power transmission over long distances involves resistance losses in the cable conductors, reactive power losses in AC systems, and the challenge of matching the varying power demands of variable-speed equipment to a supply system that must remain stable under all load conditions.
Variable Speed Drives: Controlling Subsea Motors
The motors that drive subsea pumps and compressors are electrically identical in principle to motors used in onshore industrial applications — they are typically high-power permanent magnet synchronous motors (PMSMs) or induction motors, optimised for high torque density and efficiency. What distinguishes subsea motors is their construction: they are fully sealed against the external pressure environment (rated for depths to 3,000 metres or more), oil-filled or pressure-compensated to prevent the motor winding insulation from being subjected to differential pressure, and designed for reliability over a 20-30 year service life without maintenance access.
Variable Speed Drives control motor speed by varying the frequency of the alternating current supplied to the motor. A motor running at 40 Hz rather than 50 Hz will run at 80% of its design speed; at 60 Hz it will run at 120%. This speed control capability allows operators to adjust the output of a subsea pump or compressor to match varying production rates, reservoir pressures, and process conditions — without the energy losses of throttle valves or bypass systems that would be the alternative in a fixed-speed installation.
The challenge with subsea VSDs is heat dissipation. Power electronics generate heat — a 5 MW VSD operating at 97% efficiency dissipates 150 kW as heat. Onshore, this heat is removed by forced air cooling or water cooling. Subsea, the heat must be removed through conduction into the surrounding water or through an oil-cooling circuit connected to a topside heat exchanger. Subsea VSD designs from ABB (now Hitachi Energy), Siemens Energy, and Baker Hughes all use oil-filled heat transfer circuits with careful thermal management to maintain electronic component temperatures within safe operating limits over decades of continuous operation.
Power Transmission Architecture
The power transmission architecture for a major subsea processing installation depends on the distance from the power source and the total power required. For short distances (less than 10-15 km) and moderate power (up to 10-15 MW), medium-voltage AC (MVAC) transmission at 12-33 kV is typically used. The power umbilical carries medium-voltage AC power alongside hydraulic and chemical injection lines and fibre optic communications in a combined service umbilical structure.
For longer distances (15-100+ km) or higher power levels, MVAC becomes impractical due to reactive power losses and the need for very large conductor cross-sections. The solution is medium-voltage DC (MVDC) or high-voltage DC (HVDC) transmission — using DC rather than AC to avoid reactive power losses, converting the power back to the required AC frequency at the subsea distribution node. This approach, drawn directly from the HVDC technology used in onshore long-distance power transmission, requires subsea power conversion equipment (rectifiers and inverters) that must operate reliably at depth.
The components in a long-distance subsea power system — subsea transformers, subsea switchgear, subsea VSDs, and subsea motor control centres — form what is effectively an industrial electrical substation distributed across multiple pressure vessels on the seabed. Each component must meet the same reliability standards as the other subsea equipment with which it coexists, with mean time between failures measured in decades rather than years. The qualification requirements — covering pressure testing, accelerated life testing, electrical insulation testing, and qualification against subsea environmental standards — are extensive and add substantial lead time and cost to subsea power system development.
Commercial Deployments and Technology Readiness
The subsea power distribution technology stack has been proven at commercial scale through the Åsgard subsea compression project (40 km power cable, medium-voltage AC) and several other NCS projects. Equinor’s planned electrification of the Troll C field involves a 67 km subsea power cable system, and longer-distance systems are in FEED for several future NCS projects.
The ABB-led SEPS (Subsea Electrical Power System) project — a joint industry programme that developed and qualified all-subsea 12 kV, 100 km power transmission capability — has been a key technology development programme for the industry, with the resulting technology now being incorporated into project specifications for future long-distance subsea processing deployments. Siemens Energy’s Blue Volta subsea power distribution concept provides an alternative architecture for modular subsea power distribution.
The technology readiness level for subsea power distribution in the 5-20 MW range at distances up to 100 km is broadly commercial — meaning that projects can be sanctioned with confidence in the technology, though not without accepting some technology risk premium in the development cost. For powers above 20 MW or distances above 100 km, the technology is in advanced development with qualification programmes ongoing, pointing toward commercial availability in the late 2020s. This technology trajectory is broadly consistent with the demand timeline for the largest subsea processing applications — the ambitious subsea factory vision remains a few years ahead of the power technology, but the gap is closing.